Title STUDIES ON EFFICIENCY OF ELECTRIC PUMPSETS IN PUNJAB
Author Name M.P. Kaushal
Abstract

A study was conducted to evaluate the operational efficiency of Electric Pumping Sets in Punjab and to indemnify the reasons of low efficiency wherever it occured and to suggest remedial measures thereof with a view to improve upon the existing level of efficiency. 100 tubewells  were tested. About 67 per cent of the tubewells were found to have efficiency less than 50 per cent. Major reasons for low efficiency were Identified as excessive suction lift, improper selection of pump, use of sharp bends, use of inefficient reflux valve and poor maintenance of pumping sets . Results of improvement in the efficiency by rectification of the defects have been reported.

Keyword electric pumpsets , punjab , ,
Citation Link View Link
Save